Instruction manual MOTOMAN-UP20Page: 26Incorporated wire and airductMOTOMAN ROBOTICS EUROPECreated: 00-03-17 Revised: 00-03-227.2 Incorporated wire and airductWires and an air line are incorporated into the manipulator for user application. There are 16 wires and an air duct rating. The allowable current for wires must be 3A or below for each wire. (The total current value for pins 1 to 16 must be 40A or below). The maximum pressure for the air duct is 490 kPa and its inside diameter is Ø6.5 mm.The same pin number (1-16) of two connectors is connected in the lead line of single 0.2 mm², 0.75 mm² or 1.25 mm².Cable connector provided on U-axis is type JL05-2A-20-29SC (with cap) Mating plug type is JL05-6A20-29PAir outlet: PT3/8 with pressure plugCable connector provided on S-axis is type JL05-2A-20-29PC (with cap) Mating plug type is JL05-6A20-29SAAir inlet: PT3/8 with pressure plugView AFig.19 Incorporated wire and airduct1 2 3 4 5 6 7 8 9 10 11(0.75mm²) 12(0.75mm²) 13(1.25mm²) 14(1.25mm²) 15(1.25mm²) 16(1.25mm²)12345678910111213141516Pins used numberInternal wires: 0.2mm², 10 wires: 0.75mm², 2 wires : 1.25mm², 4 wiresFig.20 Detailed drawing of connector pin numbers